JRI - Specialists in Orthopaedic Implant and Instrumentation
homeabout usimplantsinstrumentationresultshistologylinksnewseducationsurgeon infocontact us
JRI product rangeJRI product rangeJRI product rangeJRI product range
JRI Products
femoral stems
acetablular cups
hemiarthroplasty products

The FurlongŪ Straight Stem Modular System

JRI introduce an additional range to the Modular System, manufactured in High Nitrogen Stainless Steel. This extension to the product range also includes a 5mm lateral offset option for both the primary and revision ranges in order to allow for a more exact replication of the patients normal anatomy. High nitrogen stainless steel is regarded as the preferred material for femoral stems used with cement. This material has greater fatigue strength and corrosion resistance over the conventional stainless steel and the higher Young's modulus of elasticity,compared to titanium alloy, decreases stresses in the cement mantle.

The Furlong® Modular System

The Furlong® Modular System for use with cement is based on the time proven Furlong® Straight Stem Monobloc prosthesis. Since 1979 tens of thousands of Furlong® Straight Stems have been implanted with predictable good results. The stem design has remained unchanged since its inception.

The stem ensures the benefits of "state-of-the-art" cementing techniques:-

  • Straight
  • Collarless
  • Double Tapered
  • Polished

Published results(1) demonstrate the efficacy of the Furlong® Straight Stem design, a success rate of 97.3% over a five year period. These results compare very favourably against other cemented prostheses used under similar conditions such as Charnley and Howse II demonstrating failure rates of 3% and 5% respectively over a five year period.(2&3)

These results are particularly relevant as the total hip replacements were carried out by many surgeons at different levels. Often results are quoted only from specialist centres which are not reproducible at regional hospitals.

Thus the Furlong® Straight Stem Modular System as a technically straightforward but comprehensive system provides good reproducible results at reasonable cost.

The femoral stem is available in High nitrogen Stainless Steel, which is regarded as the preferred material for femoral stems used with cement.

The 12 / 14 taper allows use of a multiplicity of femoral heads, made of ceramic or stainless steel. The use of a ceramic head decreases friction and wear by a factor of ten.

The multiple choice is attractive to the surgeon as is the lower stocking necessity to hospitals and clinics. The variety of cups available add to the versatility of the system.

Acetabular cups are available for use with cement or coated with Supravit® Hydroxy-apatite Ceramic, which does not require cement, thus allowing cement/cement free hybrids.

References:

1. Warren P J, O'Doherty D, Scott G & Greenough CG (1993) The Furlong total hip : satisfactory interim results of a new cemented arthroplasty. Journal of Orthopaedic Rheumatology 6, 33 - 36

2. Beckenbaugh R D and Ilstrup D M (1978) Total hip arthroplasty. A review of three hundred and thirty three cases with long follow up. J Bone Joint Surg 60-A 306 - 313

3. Roberts J A, Finlayson D F & Freeman P A (1987) The long-term results of the Howse total hip arthroplasty. J Bone Joint Surg 62-B, 545 - 55

STANDARD STEM  
Stainless Steel
74.08.00
Extra Extra Small Section
74.10.00
Extra Small Section
74.12.00
Small Section
74.15.00
Medium Section
74.18.00 Large Section

[top]

STANDARD STEM, 5mm Offset  
Stainless Steel
74.08.05
Extra Extra Small Section
74.10.05
Extra Small Section
74.12.05
Small Section
74.15.05
Medium Section
74.18.05 Large Section

[top]

REVISION STEM, 200mm Long  
Stainless Steel
74.12.20
Small Section
74.15.20
Medium Section
74.18.20 Large Section
REVISION STEM, 300mm Long
Stainless Steel
74.12.30
Small Section
74.15.30
Medium Section
74.18.30 Large Section

[top]

REVISION STEM, 200mm Long, 5mm Offset  
Stainless Steel
74.12.25
Small Section
74.15.25
Medium Section
74.18.25 Large Section
REVISION STEM, 300mm Long, 5mm Offset
Stainless Steel
74.12.35
Small Section
74.15.35
Medium Section
74.18.35 Large Section

[top]

Femoral heads are available in Stainless Steel and Ceramic.

STAINLESS STEEL HEADS 28mm O/D  
93.28.10
Short Neck
93.28.20
Medium Neck
93.28.30
Long Neck
93.28.40 Extra Long Neck
STAINLESS STEEL HEADS 32mm O/D
93.32.10
Short Neck
93.32.20
Medium Neck
93.32.30
Long Neck
93.32.40 Extra Long Neck
Also available in 22.25mm O/D and with longer neck lengths.

[top]

CERAMIC HEADS 28mm O/D
Alumina Oxide
92.28.10
Short Neck
92.28.20
Medium Neck
92.28.30 Long Neck
CERAMIC HEADS 32mm O/D
Alumina Oxide
92.32.10
Short Neck
92.32.20
Medium Neck
92.32.30 Long Neck
Also available in 22.25mm O/D and with longer neck lengths.

[top]

The modularity of the system allows for the use of Furlong® H-A.C. Coated Acetabular Cups (please browse through the drop down menu above) or JRI Cemented Muller Cups.

JRI CEMENTED ACETABULAR CUP, 28mm I/D
U.H.M.W. Polyethylene
02.28.04
44mm O/D
02.28.06
47mm O/D
02.28.01
50mm O/D
02.28.08
54mm O/D
02.28.09
58mm O/D
02.28.10 62mm O/D
JRI CEMENTED ACETABULAR CUP, 32mm I/D
U.H.M.W. Polyethylene
02.32.06
47mm O/D
02.32.01
50mm O/D
02.32.08
54mm O/D
02.32.09
58mm O/D
02.32.10 62mm O/D
Also available in 22.25mm I/D

[top]

This system also allows for the use of Acetabular Support Rings if required.

ACETABULAR SUPPORT RINGS
Titanium
16.44.10
44mm
16.47.10
47mm
16.50.10
50mm
16.54.10 54mm
A.S.R. BONE SCREW - 2.5 AF (boxes of 6, packed sterile)
Titanium Alloy
55.22.64 22mm

[top]

Standard primary implant
5mm offset primary implant
Standard revision implant
5mm offset revision implant
Femoral heads
JRI Cemented Muller Cups
Acetabular Support Rings
   Customer Service Tel : +44 (0) 114 257 3333    Head Office Tel : +44 (0) 20 7487 4477    Email Us Accessibility | Site Map   